Handling Pacemakers and Implantable Cardioverter Defibrillators in the Operating Room

  • Chapter
  • First Online:
Principles of Perioperative Safety and Efficiency
  • 91 Accesses

Abstract

The high rate of utilization of cardiac implantable electronic devices (CIEDs) and the high stakes in case of malfunction makes it crucial that we understand and optimize the perioperative management of CIEDs. Several professional societies have addressed the topic. The function of CIED can be altered by electromagnetic interference (EMI), potentially causing iatrogenic adverse outcomes. There are several sources of EMI in the operating room. A comprehensive preoperative assessment for patients with CIED undergoing elective surgery should be performed. Device interrogation and appropriate reprogramming, if necessary, should be done before the surgical intervention. Reprogramming can be performed using a reprogramming machine or through magnet application in certain conditions. Several factors should be considered during the intraoperative period that are centered on continuous monitoring and preparedness for emergencies. Transcutaneous/defibrillator pads should be placed on the patient during the surgical procedure. Postoperative management includes reactivation of CIED and appropriate device interrogation to check for any malfunction during or following the surgical procedure.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 199.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Kremers MS, Hammill SC, Berul CI, Koutras C, Curtis JS, Wang Y, et al. The national ICD registry report: version 2.1 including leads and pediatrics for years 2010 and 2011. Heart Rhythm. 2013;10(4):e59–65.

    Article  PubMed  Google Scholar 

  2. Pokorney SD, Miller AL, Chen AY, Thomas L, Fonarow GC, De Lemos JA, et al. Implantable cardioverter-defibrillator use among Medicare patients with low ejection fraction after acute myocardial infarction. JAMA. 2015;313(24):2433–40.

    Article  CAS  PubMed  Google Scholar 

  3. Rooke GA, Bowdle TA. Perioperative management of pacemakers and implantable cardioverter defibrillators: it’s not just about the magnet. Anesth Analg. 2013;117(2):292–4.

    Article  PubMed  Google Scholar 

  4. Schulman PM, Rozner MA, Sera V, Stecker EC. Patients with pacemaker or implantable cardioverter-defibrillator. Med Clin. 2013;97(6):1051–75.

    Google Scholar 

  5. Misiri J, Kusumoto F, Goldschlager N. Electromagnetic interference and implanted cardiac devices: the nonmedical environment (part I). Clin Cardiol. 2012;35(5):276–80.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Lau W, Corcoran SJ, Mond HG. Pacemaker tachycardia in a minute ventilation rate-adaptive pacemaker induced by electrocardiographic monitoring. Pacing Clin Electrophysiol. 2006;29(4):438–40.

    Article  PubMed  Google Scholar 

  7. Crossley GH, Poole JE, Rozner MA, Asirvatham SJ, Cheng A, Chung MK, et al. The Heart Rhythm Society (HRS)/American Society of Anesthesiologists (ASA) expert consensus statement on the perioperative management of patients with implantable defibrillators, pacemakers and arrhythmia monitors: facilities and patient management. Heart Rhythm. 2011;8(7):1114–54.

    Article  PubMed  Google Scholar 

  8. Stone ME, Salter B, Fischer A. Perioperative management of patients with cardiac implantable electronic devices. Br J Anaesth. 2011;107(suppl_1):i16–26.

    Article  PubMed  Google Scholar 

  9. Schulman PM, Rozner MA. Case report: use caution when applying magnets to pacemakers or defibrillators for surgery. Anesth Analg. 2013;117(2):422–7.

    Article  PubMed  Google Scholar 

  10. Carlson T, Andrell P, Ekre O, Edvardsson N, Holmgren C, Jacobsson F, et al. Interference of transcutaneous electrical nerve stimulation with permanent ventricular stimulation: a new clinical problem? Europace. 2008;11(3):364–9.

    Article  PubMed  Google Scholar 

  11. Plakke MJ, Maisonave Y, Daley SM. Radiofrequency scanning for retained surgical items can cause electromagnetic interference and pacing inhibition if an asynchronous pacing mode is not applied. A A Case Rep. 2016;6(6):143–5.

    Article  PubMed  Google Scholar 

  12. Miller RD, Eriksson LI, Fleisher LA, Wiener-Kronish JP, Cohen NH, Young WL, editors. Miller’s anesthesia. Philadelphia: Elsevier Health Sciences; 2014.

    Google Scholar 

  13. Reddy VY, Exner DV, Cantillon DJ, Doshi R, Bunch TJ, Tomassoni GF, et al. Percutaneous implantation of an entirely intracardiac leadless pacemaker. N Engl J Med. 2015;373(12):1125–35.

    Article  CAS  PubMed  Google Scholar 

  14. American Society of Anesthesiologists. Practice advisory for the perioperative management of patients with cardiac implantable electronic devices: pacemakers and implantable cardioverter-defibrillators: an updated report by the American Society of Anesthesiologists task force on perioperative management of patients with cardiac implantable electronic devices. Anesthesiology. 2011;114(2):247–61.

    Article  Google Scholar 

  15. Badrinath SS, Bhaskaran S, Sundararaj I, Rao BS, Mukesh BN. Mortality and morbidity associated with ophthalmic surgery. Ophthalmic Surg Lasers. 1995;26(6):535–41.

    Article  CAS  PubMed  Google Scholar 

  16. Pili-Floury S, Farah E, Samain E, Schauvliege F, Marty J. Perioperative outcome of pacemaker patients undergoing non-cardiac surgery. Eur J Anaesthesiol. 2008;25(6):514–6.

    Article  CAS  PubMed  Google Scholar 

  17. Mark JB. Atlas of cardiovascular monitoring. London: Churchill Livingstone; 1998.

    Google Scholar 

  18. Donnelly P, Pal N, Herity NA. Perioperative management of patients with implantable cardioverter defibrillators. Ulster Med J. 2007;76(2):66.

    PubMed  PubMed Central  Google Scholar 

  19. Miller RD, Eriksson LI, Fleisher LA, Wiener-Kronish JP, Young WL, editors. Miller’s anesthesia. Philadelphia: Elsevier Health Sciences; 2010.

    Google Scholar 

  20. Healey JS, Merchant R, Simpson C, Tang T, Beardsall M, Tung S, et al. Canadian Cardiovascular Society/Canadian Anesthesiologists’ Society/Canadian Heart Rhythm Society joint position statement on the perioperative management of patients with implanted pacemakers, defibrillators, and neurostimulating devices. Can J Cardiol. 2012;28(2):141–51.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marwan M. Refaat .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2024 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Sabra, M., Refaat, M.M. (2024). Handling Pacemakers and Implantable Cardioverter Defibrillators in the Operating Room. In: Hoballah, J.J., Kaafarani, H.M., Tsoulfas, G. (eds) Principles of Perioperative Safety and Efficiency. Springer, Cham. https://doi.org/10.1007/978-3-031-41089-5_8

Download citation

  • DOI: https://doi.org/10.1007/978-3-031-41089-5_8

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-031-41088-8

  • Online ISBN: 978-3-031-41089-5

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics